It’s easy to see two warehouses have those same racks, the same 30-foot ceiling, and the same number of lights, and yet they look so different. One is so clear, the other is so soft, but slightly yellow. This might be because of the color temperature of the lights.
When settling on an industrial LED high bay, among the first considerations to make is color temperature. Unlike most other types of lights, these types can last for as many as 10 years, which is why it is vital to make the right choice.
What Does A Kelvin Number Actually Tell You?
Color temperature is a measure of a white light. It is measured in ‘Kelvin’ (K). The lower the number, the higher the colour temperature and the bluer the light. The higher the number, the lower the temperature of the light; the lower the number, the higher the temperature. Most of the industrial lighting products come in various colors such as 3000K through 4000 K, 5000 K, and 6500 K.
They look like this:
- 3000K: Warm white, slightly yellow. It resembles the light from old-fashioned incandescent bulbs.
- 4000K: Neutral white. It looks neither completely yellow nor completely blue.
- 5000K: Cool white. It provides a clear view, as light does.
- 6500K: Very cool white, with a prominent blue tint.
Keep in mind that Kelvin is no measure of brightness or heat. A 5000K light can’t produce as much light as a 4000K light that does the same. The light that comes from an industrial source is not the same color temperature as that given out by the other sources, and does not affect what is seen when something is lit.
Why Does It Matter So Much In A High-Ceiling Space?
Warm lights in the overhead space significantly impact the look of the interior in larger facilities. Cooler light is more likely to feel like more light even if its total light output is the same. It can also enhance the visibility of labels, floor demarcation, and edges.
This is also a point to consider for the comfort of workers. The lights can be used for 8 to 10 hours per day. Excessively blue light can be uncomfortable; for example, if there are bright lights that create glare for them.
How Do The Main Options Compare?
When Does 3000K Warm White Make Sense?
The timing of which 3000K warm white is suitable makes a significant difference when considering its application.
Lighting with 3000K is better for smaller spaces that require a more subdued luminance. It can be used in a break room, office, and small workshop.
Generally, it’s not the first thing that’s considered in a large warehouse or production line, though. These areas tend to feel gloomy due to its yellowish appearance. May also cause difficulty with some colors.
Why Is 4000K Neutral White A Safe Middle Ground?
In the 4000K range, it will offer good illumination but isn’t quite as intense. It will provide support for detail work and also provide a comfortable atmosphere.
It’s commonly installed in manufacturing units, maintenance shops, mixed‐use buildings, and more. It also reproduces well in rooms with big windows, as they blend seamlessly with the daylight.
Why Do So Many Warehouses Pick 5000K Cool White?
5000K light is daylight, clear, and free from color cast. It aids workers in reading labels, viewing objects in aisles, and safely navigating large areas.
That’s why many industrial LEDs are available in 5000K. Additionally, some models come with a switch during installation for choosing 4000K or 5000K.
Is 6500K Very Cool White Ever The Right Call?
In some situations, however, 6500K will help, and sometimes a higher in-Kelvin number isn’t necessarily brighter. The blue shade could be harsh when it comes to bright lighting that hits directly in a person’s line of sight.
It also may not be comfortable for some workers during long shifts. Test out a few fixtures in the actual space before selecting 6500K. Examine the glare and discuss light intensity with workers.
Which Color Temperature Fits Which Space?
Tall Rack Warehouses: A warehouse with high racks and frequent forklift activity will typically be 4000K or 5000K. Laborers should be able to read small labels, and truck drivers should be able to see people, pallets, and other things.
Manufacturing plants: This will be determined by the product and activities. Cooler light is recommended for the areas where dark parts are handled by workers. Spaces that are shiny metal or white, however, may prefer a more neutral 4000K. There can be undesirable glare when the lighting emitted is cooler.
Workshops: Reading tool marks, cutting, and welding require sufficient light in workshops. Their styles are typically neutral or cool in color. 4000K could be a more pleasant color in the case of people who have to spend extended periods in such locations.
Does Color Temperature Affect Energy Use?
Industrial color temperature is not directly tied to energy consumption. The amount of electricity consumed by two fixtures can be similar, even if they emit 4000K light or 5000K light and are the same in other ways.
The major influences on energy use are lumens per watt, lighting controls, and fixture wattage. Also, take advantage of motion sensors and/or light dimming.
There are other ways color temperature impacts warehouse lighting efficiency. Appropriate lighting will ensure that people working on tasks can see the job. Lighting is not only a way to save on energy costs, but can also help to make an environment safer in darker areas, as it enhances visibility. Switching to 5000K or 6500K will not reduce the electric bill.
What Else Should You Check Before Buying Industrial LED High Bay?
To be honest, it’s the easy one: Kelvin. When comparing LED high bay lights, there are other numbers on the spec sheet that are just as important. Lumens indicate the amount of light emitted from a fixture, but what matters is how much will get to the floor or workbench, which will depend on the height of the fixture and the arrangement. Different output and optics are required for a fixture at 35 feet, compared to a fixture at 20 feet.
Light spreads out in the form of a beam angle. Light is pushed down by narrow beams, tall and skinny aisles betwixt and between racks; wide beams for open floor. One of the aspects that CRI deals with is how true colors will appear. Control of glare, by using smarter lenses, diffusers, or both, is an important consideration for any forklift driver or anyone’s eyes that wander around the building. Spacing determines the location of the shadows and dark spots. Aisles, which are unused much of the day, may reduce the light level with a dimming or occupancy sensor.
Everything complements each other. A problem with the brightness of the fixture cannot be corrected by the right color temperature and a poor installation because the fixture is too low, not properly aimed, or too glaring.
How Should You Plan The Whole System?
Great industrial lighting systems are done in accordance with the actual building, rather than picked up off a catalog page. Examine the layout and ceiling height, the heights of the racks, activities going on, the hours that the place is open, and any light regulations.
If replacing old metal halide and fluorescent fixtures, walk around the building before and after work hours. Avoid low spots in aisles, eye-level light in the eyes of the forklift operator, lights that go on for the day but are only used occasionally, or dark areas between lights. Then it allows a lighting professional to compile a photometric drawing that indicates the number of items required, their placement, and expected lighting levels before anything is ordered. When choosing types of fixtures, reviewing a specific range, such as CIRC Lighting’s industrial lighting collection, can be of assistance. Some areas may also have requirements that are established by local codes and standards: read them as well.
So, Which One Should You Pick?
There is no single solution for all buildings. In most cases, 4500K or 5000K is sufficient to meet the needs of warehouses and distribution centers. For mixed spaces, workshops, and inspection spaces, the CRI is just as important as the Kelvin, and for narrower uses, 3000K and 6500K are preferred. The right industrial LED high bay solution is dependent on the tasks being performed and what everyone needs to clearly see; a lighting design that considers both output, spread, and glare, in addition to color.